SHALLOW
WELL
JET PUMP TANK
SYSTEM
MODEL #SJ05SAT20H
QUICK REFERENCE GUIDE.
SEE INSTRUCTION MANUAL FOR
COMPLETE DETAILS.
5
4
CHECK TANK PRESSURE
1. Completely drain all water
from tank by turning off pump
and opening a faucet until
water stops.
2. Use a pressure gauge to ensure
it's set to 18 psi.
To House
a. Use a tire pump to adjust the
psi to 18 psi
Vent plug
b. If water leaks from the air
release valve, replace the
pressure tank.
a. Remove pressure gauge or discharge
tee plug (not included) from the top of the
discharge tee (not included). Remove the
Pressure
vent plug in front of the discharge tee.
gauge
Air release valve
Set to
18 psi
For use with a pressure tank. Do not use for irrigation applications.
1
CAUTION: Make certain that the power source
matches the pump requirements. Pump has a
dual voltage motor and can run on 115 V or
230 V. Pump is pre-set at the factory to run
on 230 V.
To change pump/tank voltage, remove the
square voltage switch cover at the top of pump/
tank and move the voltage switch as shown.
Switch cover
Voltage Switch
115 V
Setting
CAUTION: All pumps must be primed by filling the cavity with water before they are first operated. This will take several gallons of
water, as the suction line must be filled in addition to the cavity of pump. Depending on the length of suction pipe, many gallons may be
needed to fill the entire system.
Pressure Gauge or
Discharge tee plug
Discharge
Tee
Tank Tee
b. Slowly fill the discharge tee with water
2
a. Remove plastic
plug from suction
opening.
c. Air pressure in the tank must be 2 PSI
lower than the "cut-in" of the pressure
switch. Pump/tank has a 20/40 PSI
pressure switch, so tank pressure must
230 V
be set at 18 PSI. Check pressure with
Setting
a tire gauge (not included) and add or
subtract air as needed.
Discharge
To House
Tee
Vent plug
opening
until water overflows the vent plug
opening. NOTE: Before turning on
pump, loosely replace vent plug and open
several outlets or faucets to allow water
flow during priming.
3
b. Connect pump/tank to
Connect discharge tee and pressure gauge or
well as shown. Connect
discharge plug (all not included) to tank tee.
1-1/4 in. pipe (not
included) to the pump
suction opening.
1 in. Discharge Pipe
To Home
Pressure Gauge or
Discharge tee plug
Discharge
To House
Tee
Tank Tee
Vent plug
c. Check to be sure water in the cavity
of pump stays constant. If water level
goes down, it could indicate a leak in
the foot valve, check valve or suction
pipe. If water remains constant, wrap the
pressure gauge or discharge tee plug and
vent plug threads with thread tape and
thread into pump. Tighten with wrench
(not included).
Discharge
Tee
Tank Tee
6
Connect the two wires from
the power supply to the two
open terminals on the pressure
switch. Connect the green
ground wire from the power
supply to the open green
ground screw in the pressure
switch.
Open
Terminals
Wire
Wire from
From
Power
Motor
Supply
Ground
Screws
Printed in the U.S.A.