Connect the solar panel using the Anderson to MC4 cable.
1.The input of the solar panel can be up to 500W and the maximum voltage
is 50V.
2. lf the equipment is damaged by exceeding the maximum voltage, it is
outside the scope of warranty.
AC Input
10
1100W fast charging with a household socket can perform a 100% charge
within 2 hours.
※The charging of this product can directly use the socket on the wall, etc. Please do
not use extension cords and cable taps to connect several devices at the same time.
※Using a cable tap to charge several devices at the same time will cause a large
current to flow, causing cable breakage and fire risk.
※Do not use the same socket to connect other devices while charging this product.
In general, when the same wiring in the family exceeds 1500W, the safety circuit
breaker will start.
Overload Protection Button
11
When the power supply current is unstable due to lightning or other reasons,
and there is a large current input at the AC Input, in order to protect the
product, the overload protection function (safety circuit breaker) will activate
and cut off the AC input port.
Please follow the sequence below to restore the AC input function:
1) Turn off the power button and unplug all ports.
2) After confirming that there is no abnormality in each part, turn on the power button.
3) Press the overload protection button, connect the AC Cable to restore the AC input.