Ash Compressor Drawer
12 OPERATING AND MAINTENANCE INSTRUCTIONS
The ash compressor
requirements and pellet quality.
The boiler maintenance requires performing an annual cleaning of the compressor casing
12.1 Activating the empty ash compressor warning
Bioclass iC / iC DX
The
that the ash drawer is full and needs emptying. In the
is displayed its status. When full, a warning is activated, indicating the need for emptying.
By default, this function is activated and set to values for operating with manual ashtray. These
values must be updated when you install the compressor ashtray from the table below and
following the instructions in the paragraph
Boiler model
BioClass iC 12
BioClass iC 18 / iC DX 18
BioClass iC 25 / iC DX 25
BioClass iC 35 / 45
12.2 Safety warnings
For safe handling of the ash drawer, you should take the necessary safety precautions and wear
suitable clothing to protect against possible injury. Pay special attention to the following
recommendations:
- Switch off the boiler or ensure it is on pause before taking out the ash drawer. If you take out
the ash drawer with the boiler on pause, make sure you replace it before switching on the boiler
again. It is recommended to take out the ash drawer when no flame is detected in the burner.
- It is recommended to wear insulating thermal gloves to protect your hands from any burns
from hot parts of the drawer.
- It is recommended you wear a protective mask to avoid breathing in any ash particles,
particularly in the case of people with allergies or any type of respiratory problems, who should
always wear a mask when carrying out ash removal.
- As the ash to be removed from the drawer may be burning or glowing, special precautions
should be taken with regard to the type of container it is emptied into. A metal container is
recommended, or the ash should be totally extinguished on handling, using water or another
extinguishing agent.
- The ash drawer must be emptied with the boiler switched off. Never touch the screwas it could
trap your hand.
DOMUSA TEKNIK shall not be liable for any injury or damage caused to people, animals or property as
a result of incorrect handling of the ash drawer or the ash itself.
IMPORTANT: The ash drawer must only be cleaned when the boiler is switched off or on pause.
28
(24)
compressor drawer must be emptied regularly, in accordance with power
includes the option
Kg
Pellets
2000 Kg.
2200 Kg.
2800 Kg.
4000 Kg.
mpty ash compresor warning . This function warns us
"Ashtray status"
"Ashtray empty notice"
NOTE: The ashtray must be emptied every time a
new value of this parameter is set.
(18).
parameter in the
on the boiler manual.
EN
"User Menu"