26/27
04. Technical details
Unit featuring a pneumatic cylinder that activates the hydraulic device which provides the
pressure necessary to spray the product.
The unit is supplied with a suction probe, which is inserted directly in the container of the product
to be applied.
Dimensions
Net weight
Engine stroke
Pressure ratio
Pneumatic cylinder
Free flow
(60 cycles/min)
Flow per cycle
Maximum air inlet
pressure
Maximum fluid outlet
working pressure
Air consumption
at 100 bar (1,450 psi) and
5.7 CPM
Air Inlet
Product outlet
Temperature
operating range
Carriage
bracket
Directives and regulations
Directive Machine
ATEX regulation
(*) Non electric equipment in explosion hazard areas (ATEX) must have the earthing connections and/or
static-free feed hoses.
HTV 250 pneumatic pump Technical Data
46,5 x 46 x 87,5 cm.
30 Kg
44 mm.
Ø 125 mm.
42 c.c. / 0.009 g/min. / 0.011 imp Gal
BSP 1/4" Quick coupling
from -10 to +60
OK
2006/42/UE
Community directive complied with 2014/34/UE
Explosive atmosphere (Atex):
ENGLISH
HTV 250
18.3x 18.1 x 34.45" (inches)
1.73" (inches)
25:1
Ø 4.92" (inches)
2.54 L/min.
0.56 gpm
0.67 US gpm
7 bar / 102 psi
176 bar / 2,552 psi
24.31 L/min.
5.35 gpm
6.42 US gpm
BSP 1/4" BSP
o
C / from 14 to 140
Absorption
probe
II 2G T4 x (*)
66 lbs
o
F
OK

Publicidad