4. Comissionning
After correctly installing your heat pump on the hydraulic circuit of your pool or spa, the filtration pump of your pool
must be in operation in order for the water to circulate in the heat exchanger of your heat pump.
1: Make sure that the valves on your heat pump are set correctly: By Pass: open to 50%, inlet valve: open to 100%, outlet
valve: open to 70%.
2: Turn on your filtration pump and check that there are no leaks in the hydraulic circuit and that the water is circulating
properly through the pool or spa's discharge nozzles.
3: Connect the power supply and then press the ON/OFF button on the remote control. If the installation is correctly
done, the heat pump should turn on immediately.
4: After a few minutes, the air released by the fan should be significantly cooler than the ambient air.
5: When the heat pump is running, turn off the filter pump and the unit should stop.
6: Run your filtration pump and heat pump 24 hours a day until the desired temperature is reached. When the desired
temperature is reached the unit will slow down, when the temperature is maintained for 45 minutes and ; the unit will
stop and restart automatically as soon as the water temperature is 0.2 °C lower than the set temperature requested
(Attention : your filtration pump must be running for the heat pump to work).
45