MC-5457550-Bedien-1009.qxd
sharp cutting edges are less likely to
bind and are easier to control.
g Use the power tool, accessories
and tool bits etc. in accordance
with these instructions, taking into
account the working conditions and
the work to be performed. Use of
the power tool for operations different
from those intended could result in a
hazardous situation.
5 Service
a Have your power tool serviced by a
qualified repair person using only
identical replacement parts. This
will ensure that the safety of the
power tool is maintained.
b To avoid hazards, damaged power
leads must be replaced by the
manufacturer or his customer service
representative.
6 – Safety instructions
relating specifically to
the equipment
• Before using the grinder each time the
grinding disc must be given a sound
test (fig. 5) (fault-free discs emit a clear
sound when lightly tapped with, e.g. a
plastic hammer). This also applies to
new discs (as they may have been
damaged during transport). The tool
must be given a trial run without load
for at least 5 minutes. Keep well clear
of the danger zone during the trial run.
• Grinding discs must be stored in a
cool, dry place at as even a
temperature as possible.
• The grinding discs must be clamped
on only with the clamping flanges
supplied with the tool.
28.10.2009 10:21 Uhr
• Only clamping flanges of the same
size and shape should be used to
clamp the grinding discs. The lining
between the clamping flange and the
grinding disc must be of an elastic
material, e.g. rubber, soft cardboard,
etc.
• The location hole in the grinding disc
must not be re-bored.
• The work-piece supports and the
upper adjustable protective covers
must always be set as close to the
grinding disc as possible.
• Grinding discs must not be used
without protective equipment. The
following distances must not be
exceeded (fig. 3):
Work-piece support – grinding disc:
max. 2 mm
Protective equipment – grinding disc:
max. 2 mm
• Before use the work-piece support
and inspection glass must be
screwed on. Always keep the spark
protective glass clean. Maximum
permissible temperature of motor
housing: 80 °C. To ensure safe
grinding, especially in stationary use,
it is recommended to screw the tool
down.
• Always wear safety goggles when
using the grinder.
7 – Installation and setting
• Always place the tool on a stable
work surface. For stationary use
fasten the tool to the bench with four
fixing screws.
• Fit the spark protector (3) to the tool
so that there is a maximum distance
Seite 41
41