FRONT PANEL DESCRIPTION
1 DISPLAY
3 ½ digit, 7 segment, 0.5" high LCD
2 FUNCTION AND RANGE SWITCH
This switch is used to select the function and desired range as
well as to turn on the instrument. To extend the life of this battery,
the switch should be in the "OFF" position when the instrument is
not in use.
3 10A JACK
Plug in connector to red (positive) test lead for 10A measurement.
4 VΩmA JACK
Plug in connector for red (Positive) test lead for all voltage and
resistance and current (except 10A) measurements.
5 COM JACK
Plug in connector for black (negative) test lead.
SPECIFICATIONS
DC VOLTAGE
Range
Resolution
200 mV
100 μV
2000 mV
1 mV
20 V
10 mV
200 V
100 mV
600 V
1 V
OVERLOAD PROTECTION:
220V rms AC for 200mV range and
600V DC or 600V rms for all ranges.
AC VOLTAGE
Range
Resolution
200 V
10 mV
600 V
1 V
RESPONSE: Average responding, calibrated
in rms of a sine wave.
FREQUENCY RANGE: 45Hz ~ 450Hz
OVERLOAD PROTECTION: 600V DC or
600V rms for all ranges.
SW-Stahl und Werkzeugvertriebs GmbH
L
e
v
e
k r
u
s
r e
t S
a r
s
s
e
6
5
D
4 -
2
8
9
7
R
e
m
s
c
h
e
d i
Accurcy
±(0,5% +3Digit)
±(1,0% +5Digit)
±(1,2% +5Digit)
Accurcy
±(0,5% +10Digit)
Tel. +49 (0) 2191 / 46438-0
F
ax +49 (0) 2191 / 46438-40
- E
DC CURRENT
Range
Resolution
200 μA
100 nA
2000 μA
20 mA
200 mA
100 μA
10 A
10 mA
OVERLOAD PROTECTION:
0.5A/600V and 10A/600V fuse
MEASURING VOLTAGE DROP: 200mV
RESISTANCE
Range
Resolution
200 Ω
0,1 mΩ
2000 Ω
20 kΩ
200 kΩ
2000 kΩ
MAXIMUM OPEN CIRCUIT VOLTAGE: 3.0V
OVERLOAD PROTECTION:
15 seconds maximum 220V rms
M
a
: l i
n i
o f
@
s
w
s
a t
l h
d .
e
1
2
3
4
5
Accurcy
1 μA
±(1,8% +2Digit)
10 μA
±(2,0% +2Digit)
±(2,0% +10Digit)
Accurcy
±(1,0% +10Digit)
1 Ω
10 Ω
±(2,0% +4Digit)
100 Ω
1 kΩ