Descargar Imprimir esta página

Allen + Roth SPK-200L Manual Del Usuario página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
4a. Install the Threaded Nipple
( and 90 degree fitting- SPK300L)
to the Control Valve with the internal
threads facing opposite the Control Valve.
4b. Install the correct Burner Orifice depending
on your Burner Pan size and fuel source.
5. Attach Control Valve Assy. to
the Air Shutter by rotating the entire
Control Valve Assy. clockwise. Make
sure Burner Orifice is fully engaged
and the Control Valve Assy. is level
wit the Burner Pan.
6a. Attach the Pilot Bracket to the Burner Pan
with the 2 screws already attached to the
Burner Pan.
6b. Attach the Pilot Assembly to the Pilot Bracket
with 2 screws supplied.
6c. Install the correct LP or NG Pilot Orifice
depending on your fuel source.
7a. Connect the Piezo Ignition Wire to the Piezo
Ignitor.
7b. Screw the Thermocouple Line into the Control
Valve.
7c. Attach the Flex Pilot Gas Line from the Pilot
Assembly to the Control Valve. Be careful to not
kink the line during assembly.
8a. Connect the correct Fuel Pressure Regulator and
install other fitting necessary for your particular
installation.
4.
SPK-300L Control
Valve Assy.
90 Degree Fitting
4a.
Threaded Nipple
5.
6.
Pilot Assy.
LP Pilot
Orifice
7.
10
4a.
4b.
LP18 = 18" Size & LP Fuel
LP24 = 24" Size & LP Fuel
(Internal Threads)
LP30 = 30" Size & LP Fuel
NG18 = 18" Size & NG Fuel
Burner Orifice
NG24 = 24" Size & NG Fuel
LP18 = 18" Size & LP Fuel
NG30 = 30" Size & NG Fuel
4b.
LP24 = 24" Size & LP Fuel
LP30 = 30" Size & LP Fuel
NG18 = 18" Size & NG Fuel
NG24 = 24" Size & NG Fuel
NG30 = 30" Size & NG Fuel
Burner Orifice
SPK200L or SPK300L
Control Valve Assy. with
Orifice Installed
Pilot
Brkt.
Burner Pan Assy.
NG Pilot
Orifice
SPK200L
Control Valve Assy.

Publicidad

loading

Este manual también es adecuado para:

Spk-300l49762854976276