TROUBLESHOOTING
Malfunction
-The control panel does
not light up, the fan does
not start.
-Display is normal but
without air flow or the
air speed is too low
-Motor does not respond
to control panel
-Cool effect not good
-Water leaking from
drain valve
-Air diffuser / swing
function not working
-Water drops splash out
of the air diffuser
NOTE:
THIS INSTRUCTIONAL CHART IS FOR REFERENCE PURPOSES ONLY, IF ANY TECHNICAL ASSISTANCE
IS NEEDED, PLAESE CALL STAR PROGETTI'S OFFICES FOR SERVICE/REPAIR AT NO. 02/90639261 ext. 2
Reason
-No power
-Main control board failure
-Fuse is blown
-Panel failure
-The fan is jammed
-Cooling pad or dust filter is blocked
-Fan is distorted
-Main control board failure
-Main control board failure
-Panel failure
-Water tank not enough water
-Water pump is obstructed.
-Drain valve is loose
-Dirt in valve
-
ynchronous motor is burnt out
S
-Crankshaft is broken
-Water pipe has come loose
Keep the original packaging
Remedy/Solution
-Check unit is plugged in
-Change control board
-Change fuse
-Change panel
-Check to ensure there is nothing
preventing free rotation of the fan
-Clean the cooling pad and dust filter
-Change the fan
-Change the main control board
-Change the main control board
-Change panel
-Add water to ensure there is enough
water for pumping
-Clean water tank discharge
impurities.
-Tighten drain valve nut
-Clean drain valve
-Change
-Change crankshaft
-Check water pipe to top of filter pad
and reattach or tighten as necessary
27
ynchronous motor
s