Operating Temperature: 0°C - 40°C (32°F - 104°F)
Storage Temperature: -20°C - 70°C (-4°F - 158°F)
Humidity: 10-50% RH (non-condensing)
Power Requirements: 100W, 110-240VAC
Colour: Black
Connections:
Input: 4 x HDMI Type A (Female), 4 x 3-Pin Phoenix
Output: 4 x HDMI Type A (Female), 4 x 5-Pin Phoenix, 4 x Mini Toslink (Female)
Control: RS-232 (Female), RJ-45 (Female), 8 x IR 3.5mm (Female)
Power: IEC C14
Front and Rear Panel Overview
Front Panel
INPUT 1-4: Select between 4 HDMI source devices by pushing the required Input button
OUTPUT 1-4: Select between 4 HDMI displays by pushing the required Output button
LOCK: Press and hold for two seconds to lock or unlock the matrix's front panel push button control.
When the controls are locked the Lock LED will be illuminated.
ALL: Press ALL then a chosen Input and the Take button consecutively, this will switch the user's
chosen Input to output on all output displays
RES: Press Res, a chosen output, then Next. Repeatedly pressing Next will allow the user to cycle through
several output resolutions for the selected display. Press Take to select the desired resolution. When Auto
resolution is selected the optimum resolution of the display will be chosen.
EDID: Press EDID, then a chosen Input, then Next. This will allow the user to manage the EDID of the
chosen Input port. The Manual EDID setting is for EDID Management via the Matrix's control software.
NEXT: Cycles to the next option
SAVE: Press Save and a chosen Output, this will save the current layout of Inputs – Outputs under the
selected Output push button. The maximum number of possible saved layouts is 4.
RECALL: Press Recall and the same chosen Output as above to set the chosen layout from the
previously set 4 options.
CLEAR: Cancel the current command function
TAKE: Set the displayed option
Rear Panel
LAN: Control the unit using TCP/IP Control
RS-232: Control the unit using RS-232 Control
English