ENGLISH
2.
Pressurize the system with water to no more than 35 PSI.
3.
Close the valve to trap pressurized water in the system.
4.
Observe the system for leaks and/or pressure decay.
5.
For technical support please call
WARNING
When pressure testing a system with water, air
is often trapped in the system during the filling
process. This air will compress when the system is
pressurized. Should the system fail, this trapped air
can propel debris at a high speed and cause injury.
Every effort to remove trapped air must be taken,
including opening the bleed valve on the filter and
loosening the pump basket lid on the filter pump
while filling the pump.
WARNING
Trapped air in system can cause filter lid to be
blown off, which can result in death, serious
personal injury, or property damage. Be sure all air
is properly out of system before operating. DO NOT
USE COMPRESSED AIR TO PRESSURE TEST
OR CHECK FOR LEAKS.
When pressure testing the system with water, it is
very important to make sure that the pump basket
lid on the filter pump is completely secure.
Do not pressure test above 35 PSI. Pressure
testing must be done by a trained pool professional.
Circulation equipment that is not tested properly can
fail, which could result in severe injury or property
damage.
5.2
Start Up
If this is a new pool installation, make sure all piping
is clear of construction debris and has been properly
pressure tested. The filter should be checked for proper
installation, verifying all connections and clamps are
secure according to the manufacturer's recommendations.
WARNING
To avoid risk of damage or injury, verify that all
power is turned off before starting this procedure.
Polaris
PB4SQ
Booster Pump | Installation and Operation Manual
®
™
1-800-822-7933.
1.
Turn filtration pump ON.
2.
Open the filter pressure release to relieve the system
pressure until water comes out.
3.
If the filter pump is located below the water level of the
pool, opening the filter pressure release valve will prime
the pump with water.
4.
Once all the air has left the filter, close the pressure
release valve.
5.
Turn on the power to the booster pump.