19
Owner's Manual
MONTHLY
Inspect coils. Clean when dust accumulation is visible. In normal use, dust can
accumulate and can restrict airflow, reducing performance and causing the unit to
overheat.
To maintain appearance, wipe interior and exterior surfaces with a damp cloth. For
deep cleaning and a lasting, protective shine, use an automotive interior treatment
product.
AS NEEDED
Clean pump check valve and basin. This requires removal of the front housing.
Clean coils. Inspect the horizontal evaporator (cold) coil with the front cover
removed. If excessive dust and debris is present, vacuum thoroughly and/or clean
with alkaline (non-acidic) coil cleaner.
LGR 6000Li Owner's Manual
© 2023 Legend Brands, Inc.