3.6.3
Relay output 11-14
The following function can be set for the relay output:
Level control
NOTICE
The level control runs totally independently of the other functions
of the BADU OmniTronic.
Pos : 36.43 /Tec hnische D ok umentati on Speck Pum pen/Betriebs anl eitung/Beschr eibung/BADU Omnitr onic _ BADU Om ni Stellantrieb/Ausg ang z ur Eco VS-Pumpe @ 20\mod_1610098184423_370.docx @ 396641 @ 3 @ 1
3.6.4
Output to Eco VS pump
NOTICE
The pump may not switch on as long as the valve insert in the
BADU OmniTronic is rotating. Otherwise, there is a risk of a defect
in the control.
Pay attention to this during installation, starting for the first
time and operation.
The connection for the pumps BADU Eco VS, BADU Eco Touch-
Pro II and BADU Eco Soft is to be carried out as in the connection
diagram. The terminals correspond to the colours of the pump's
cables. BADU pumps may only be connected via the control
cable. The plug with network cable is to be plugged in to a
separate plug socket.
NOTICE
With the VS pump, the digital inputs are to be turned on: di = on.
See point 5.3.10 on page 48.
3.6.5
Output to the BADU Eco Drive II (frequency converter)
NOTICE
The pump may not switch on as long as the valve insert in the
BADU OmniTronic is rotating. Otherwise, there is a risk of a defect
in the control.
Pay attention to this during installation, starting for the first
time and operation.
The BADU Eco Drive II frequency converter can also be
connected directly to the BADU OmniTronic. The same output
terminal is used here as for the VS-pumps.
The following must be observed on the BADU Eco Drive II:
Set parameter 5-00 to [1] NPN
03|2022