TROUBLESHOOTING
Problem
The water inlet
leakage
The water
won't stop/flow
out
No response
for manual/rain
delay function
Short battery
life
Possible Cause
1. No filter or not be
placed horizontally
2. The faucet is not the
standard 3/4"
1. Long time in storage
and transportation
make the valve
inactive
2. Valve blockage
1. After setting manual
watering or rain delay
time, without pressing
OK button to save and
run.
1. Mixed use of old and
new batteries
2.
Use the carbon
batteries or
rechargeable
batteries
Possible Solution
1. Add a filter and make
sure it's placed
horizontally in the inlet.
2. Make sure the faucet
is a standard 3/4" faucet.
3. Wrap Teflon tape on the
tap making it tight.
1. Keep the tap turned
off and turn the timer
dial to ON;
2. Run the manual
watering for 5-7s and
stop it;
3. Repeat the Step 2 for 3
to 5 times;
4. Try using it normally.
1. Press OK button again
after the time is set to
confirm.
1. Use new alkaline
batteries.
2. Rechargeable batteries
and carbon batteries
have a short life, use
the alkaline batteries
instead of them.