Door Reversal
The illustrations for door reversal depict parts that may vary slightly between various models.
Tools required: Philips screwdriver, flat bladed screwdriver, and socket wrench set.
• Ensure the unit is unplugged and empty.
• To take the door off, it is necessary to tilt the unit backwards.
Rest the unit on something solid so that it will not slip during the door reversing process.
• All parts removed must be saved to the reinstall the door.
• Do not lay the unit flat on its back as this could damage the coolant system.
• It is recommended that two people handle the unit during assembly.
Step 1:
Carefully remove the top hinge cover with
flat screwdriver.
Step 3:
Remove the pin hole plug with a
flat screwdriver.
Step 5:
Unscrew and remove the middle hinge and
then lift the bottom door and put it on a soft
pad to avoid scratches.
Step 2:
Unscrew the top hinge with a Philips screwdriver.
Step 4:
Move the hole plug from left side to right side,
and then lift the upper door and place it on a
padded surface to prevent it from scratching.
Step 6:
Using a flathead screw driver pry up the two
hinge hole covers and move them to the other
side.