USER'S MANUAL
MULTIMETER HT1E602
Thank you for purchasing our product. Manufactured to a high standard, this
product will, if used according to these instructions, and properly mainta-
ined, give you years of trouble free performance.
This manual contains safety information, operation, specifications and ma-
intenance of the meter.
The device is used to measure DC and AC voltage, current and resistance,
continuity measurement, diodes.
The meter has functions of polarity indication, data storage, value retention,
overrange indication, Auto Power Off, NCV and RMS.
It is produced according to EN61010-1 for electronic measuring instruments
with surge category (CAT III 600 V) and pollution degree 2.
WARNING
To avoid electric shock or personal injury, observe the following
rules:
• Check the housing before using the meter. Do not use when
the meter or its housing is damaged. Look for cracks. Note the
insulation around the joints.
• Check the test leads for damaged insulation or exposed wires.
• Do not measure a voltage higher than the rated voltage specified on the
indicator.
• The rotary switch must be set in the correct position and do not change
the range during measurement.
• When voltages exceed 60 V for AC and 30 V for DC, special care must be
taken against the danger of electric shock.
• Use the appropriate terminals, functions and range for the measure-
ment.
• Do not use or store the meter in an environment with high temperature, humidity, explosives, flammable materials, high magnetic
field.
• Disconnect the power supply to the circuit and discharge the capacitors before testing resistance, continuity or diodes.
• Replace the battery as soon as the battery indicator shows a low charge. With a low battery, the meter can generate false readings.
• Disconnect the cables and switch off the meter before opening the housing.
• No changes must be made to the design and construction of the meter.
• Use a soft cloth and mild detergent for cleaning. Do not use abrasives or solvents
• The meter is suitable for indoor use.
• Turn the meter off when not in use, and remove the battery when not in use for a long time.
TECHNICAL DATA
Display:
Polarity:
Measurement method:
LCD size:
Sampling rate:
Overload indication:
Working environment:
Storage environment:
Power supply:
Low battery indication:
Static electricity:
Product size:
Product net weight:
Adres producenta/ Adresse des Herstellers/ Manufacturer's Address/ Адрес производителя
GTV Poland S.A., ul. Przejazdowa 21, 05-800 Pruszków, www.hoegert.com
LCD 3.5", digits 0.6"
automatic, indicated minus, assumed plus.
double integrated current type A / D switching
45 x 23 mm
2 times per second
„1" is displayed
0°C ~ 40°C, at relative humidity <80%
-10°C ~ 50°C, at relative humidity <85%
AAA x 2 batteries
"
about 4mA
160 x 76 x 32 mm
155 g (with batteries)
5