Descargar Imprimir esta página

Ugolini MT micro Manual De Instrucciones página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3
Assemble the faucet by reversing the
disassembly steps (see figure 10)
4
Fit bowl gasket around its seat.
Note: the largest brim of gasket must face
against the rear wall (see figure 12).
figure 12
5
Insert the magnetic outside rotor in the
evaporator taking care to accompany it to the
end (see figure 13).
figure 13
6
Install the outer spiral. Slide it over the
evaporator until its hexagonal front notch
engages with the hexagonal exposed end of the
magnetic outside rotor (see figure 14).
7
Push the bowl towards the rear wall of the
unit until it fits snugly around the gasket and its
front fastening hooks are properly engaged (see
figure 15).
8
Use fresh product to chase any remaining
sanitizer from the bottom of the bowl(s). Drain
this solution. Do not rinse out the machine.
7. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the
machine may be performed, if needed, only as
f u r t h e r p r e c a u t i o n , i n a d d i t i o n t o t h e
Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare a solution of hot water (45-60°C)
and sodium hypochlorite (bleach) at a ratio of
200 ppm per 2 litres of water.