In case of a Wallflex type "SC" (external mount),
where the extraction arm is mounted separately
from the filter unit, the reinforcement plate is not
necessary. In that case, proceed with par. 4.3.2.
To install the reinforcement plate, do the following.
Fig. 4.1
Insert the 4 cage nuts M12 from the inside in the
corresponding positions of the plate;
- PolyArticule H-160 / arm Ø 160 mm: inner positions (A)
Fig. 4.1
Cage nuts
Fig. 4.2
Determine on which side
arm (left or right).
Install the reinforcement plate on that side of the filter unit
with the 7 flange bolts M6x16.
Fig. 4.2 Mounting of the reinforcement plate
4.3.2
Inlet flange + non-return valve (assembly)
Applies to all types
of units
You must install the assembly, that consists of an inlet flange
with non-return valve, on the side panel of the filter unit. In
case of a Wallflex 2400, you must install an assembly on both
side panels.
The side panels are universal, so you can install
them either left or right.
To install the assembly, do the following.
10. The outer positions (B) are not applicable
11. In case of a Wallflex 2400 you must install a reinforcement plate on both sides
86958015
you want to install the extraction
11
Fig. 4.3
Depending on the mounting position
inside of the side panel.
Put sealing material (E) around the inlet opening on the
inside of the side panel.
Insert the assembly from the inside of the panel through
the opening. Make sure that the axis of the non-return
valve is in vertical position (B).
Attach the assembly (A) to the side panel with the 6 bolts
M6, washers and nuts.
10
Secure the non-return valve to the inlet flange with 2
self-tapping screws (F+G). Two small holes in the inlet
flange indicate the correct position. Make sure that you
install one screw on top and the other one at the bottom of
the assembly.
Make sure that the non-return valve can fully open.
In case of a LL-5.5/24 | Manual on/off switch on the
hood, incl. LED working light (option)
Install the cable gland M16 + nut M16 (C).
If not:
Install the screw plug M16 + nut M16 (D).
B
A
C
D
Fig. 4.3 Inlet flange + non-return valve (assembly)
4.3.3
Side panel
Applies to:
Make sure that you have the 4 bolts M12 at hand
that you need to install the arm bracket.
For the correct use of SealApplicator, refer to the
instruction sheet that is supplied with the spray
bottle.
Refer to Fig. V on page 98 for the exact mounting
position of the side panel with respect to the cover
plates (top + bottom).
Fig. 4.4
(1) Remove the backing material of the seals.
(2) Spray SealApplicator lubricant on the seals
(3) Put the side panel within 60 seconds
unit.
12. On the left or right side of the filter unit
13. By the use of SealApplicator you can slightly shift the side panel to get the
right position. After approx. 60 seconds the lubricant is dry so you cannot shift
anymore.
14. After approx. 60 seconds SealApplicator lubricant loses its functions and you
cannot shift anymore.
, determine the
12
E
CSC
.
13
on the filter
14
EN | 6

Publicidad

loading