System "B": (P9.P10) 
 
In  case  of  impossibility  to  install  the 
 
drainage  pipe  as  showed  on  "A"  system, 
 
please  use  system  "B"  to  drain  the 
 
condensate moisture to a suitable place.  
 
If  use  system  "B",  please  block  the  black 
 
rubber cup from system "A".  
 
Take  out  the  cover  from  the  unit, and  cut 
 
the cover as the label shows, then connect 
 
the drainage pipe from the bottom system 
 
"B"  hole.    (3.10  will  show  how  to  remove 
 
and fix the cover accordingly) 
 
Usually "B"  holes is used in the installation 
 
when the outside temperature is very low, 
 
and  in  this  way  we  prevent  no  ice  in  the 
 
discharge water pipe.  
 
This solution is used also to be much easy 
 
for  the  installer  to  connect  the  internal 
 
drainage  pipe  when  he  does  not  want  to 
 
see the pipe from outside. 
 
2.4 FASTENING THE BRACKET (P11) 
 
‐Drill the holes for anchoring the fastening 
 
bracket to the wall using preferably the 9 
 
holes  showed  in  black  on  the  paper 
 
template.  
 
‐The anchor bolts provided require a 8mm 
 
hole.  The  wall  should  be  inspected  to 
 
determine if provided bolts are useful or if 
 
it  is  necessary  to  use  a  different 
 
anchorage.  The  manual  facture  is  not 
 
liable  in  case  of  underestimation  of  the 
 
structural  consistency  of  the  anchorage 
 
made at the time of installation. 
 
 
 
2.5 INSTALLATION OF THE PIPES (P12) 
 
‐  After  drilling  the  holes,  the  plastic  sheet 
 
supplied  with  the  air  conditioner  need  to  be 
 
fitted through them. 
 
‐ Measure the depth of the wall and cut supplied 
 
plastic sheet. 
 
‐ Roll the sheet and insert it into the hole, paying 
 
attention to the joint line, which must be always 
 
upper  position.  Remember  that  the  sheet  must 
 
have the same inclination of the holes(min 3°). 
 
 
 
 
 
 
P9
P11
P12
EN 
P10
9