SOLUTIONS FOR POSSIBLE PROBLEMS
The following are instances of malfunctioning that can be observed when Honey Liquifier Cabinets are used.
FAULTS
The cabinet will not heat up
Cabinet interior overheating
Cabinet
interior
heating
Fan not working
LEGA
srl
Costruzioni Apistiche – via Maestri del Lavoro 23 – 48018 Faenza
www.legaitaly.com - Tel 054626834 – Fax 054628279 – P.iva 00043230390
POSSIBLE CAUSES
No power from line
Faulty resistors
Faulty thermostat.
Dirty thermostat probe.
insufficient
Faulty fan
Clogged ventilation grids
Faulty resistor
Faulty fan
Jammed fan
REMEDIES
Check that the cabinet has been
correctly plugged in.
Check that switch is set to "
Check for line power supply to the
socket used.
Unplug the device immediately and
contact a specialised after-sales
centre.
Unplug the device immediately and
contact a specialised after-sales
centre.
Clean the thermostat probe.
Unplug the device immediately and
contact a specialised after-sales
centre.
Clean the grids thoroughly.
Unplug the device immediately and
contact a specialised after-sales
centre.
Unplug the device immediately and
contact a specialised after-sales
centre.
Remove any objects that prevent
correct fan operation.