WARNING: This air conditioner uses R32 flammable refrigerant.
Notes: Air conditioner with R32 refrigerant, if roughly treated, may cause serious
harm to the human body or surrounding things.
*The room space for the installation, use, repair, and storage of this air conditioner should be
greater than 5 m
.
2
*The maximum load of the air conditioner is 1.7kg.
*Do not use means to accelerate the defrosting process or to clean other than those
recommended by the manufacturer.
*Do not pierce or burn air conditioner, and check the refrigerant pipeline wether be damaged.
*The appliance shall be stored in a room without continuously operating ignition sources
(forexample: open flames, an operating gas appliance or an operating electric heater.
*Notice that the refrigerant may be tasteless.
*The storage of air conditioner should be able to prevent mechanical damage caused by
accident.
*Maintenance or repair of air conditioners using R32 refrigerant must be carried out after
security check to minimize risk of incidents.
*Air conditioner must be installed with stop valve cover.
*Please read the instruction carefully before installing, using and maintaining.
Symbol
WARNINGS
Note
Explanation
WARNING
This symbol shows that this appliance uses a flammable
refrigerant. lf the refrigerant is leaked and exposed to an externa!
ignition source, there is a risk of fire. (Only for the AC with UL or
ETL-MARKING,UL60335-2-40)
WARNING
This symbol shows that this appliance uses a flammable
refrigerant. lf the refrigerant is leaked and exposed to an externa!
ignition source,there is a risk of
MARKING & CB-MARKING, IEC 60335-2-40+A 1 :2016)
CAUTION
This symbol shows that this appliance uses a low burning
velocity material. (Only for the AC with CB-MARKING,
IEC 60335-2-40:2018)
CAUTION
This symbol shows that the operation manual should be read
carefully.
CAUTION
This symbol shows that a service personnel should be handling
this equipment with reference to the installation manual.
CAUTION
This symbol shows that information is available such as the
operating manual or installation manual.
fire.(For the AC with CE-
4