Control automático de presión de bombas

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical data
Description
For pumps up to
Input and output diameter
Working pressure
Maximum operating pressure
Water maximum temperature
Conductors
Work cycle
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
Power requirements
CAUTION
Connection to the power supply must be made by an
electrical professional, following the electrical diagram on the right.
CAUTION
Use a separate electrical circuit for the pump. This circuit
must not have conductors with a gauge smaller than 12 AWG, and must be
protected with a 20 A time delay fuse. Before connecting the motor to the
power line, make sure that the voltage is equal to the voltage indicated on the
motor nameplate. Operating at a lower voltage will damage the motor.
CAUTION
The power cords are color-coded as follows:
Green: Ground
White: Neutral
Black: Line
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When using power tools outdoors use
Use". These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
Code
Voltage
Frequency
Current
50 min of work and 20 min of rest. Maximum 6 hours per day.
Insulation
The thermal insulation class of the motor wiring is: Class B
Number of
Conductors
3 (one grounded)
CPB-180
Automatic pump control
1 118 W (1.5Hp)
de 1.75 bar (25 PSI) a 3.5 bar (51 PSI)
10 bar (145 PSI)
18 AWG x 3C with insulation temperature of 221 °F
The power cable has cable clamps type: Y
The construction class of the tool is: Basic insulation.
Motor
Motor
Ground
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "Outdoors
102417
127 V
60 Hz
16 A
1"
140 °F
Class I
Authorized Service Center.
1 2
3
4 5 6
V U
N L
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
Terminal
board
Line
Line
Ground