TROUBLESHOOTING
PROBLEM
Log set produces a
clicking/ticking noise
just after burner is lit
or shut off.
Log set produces
unwanted odors.
Gas odor even
when control knob is
in OFF position.
Gas odor during
combustion.
Whistle noise when
burner is on.
POSSIBLE CAUSE
1. Metal expanding while
heating or contracting while
cooling.
1. Log Set burning vapors
from paint, hair spray, glues,
cleaners, chemicals, new
carpet, etc. (See IMPORTANT
statement page 20).
2. Gas leak. See Warning
statement page 20.
1. Gas leak. See Warning
statement page 19.
2. Control valve defective.
1. Gas leak. See Warning
statement at top of page 19.
1. Air in gas line.
2. Control knob not in fully
open position.
3. Spiral gas flex line.
CORRECTIVE ACTION
1. This is common with most log sets. If
noise is excessive, contact qualified
service person.
1. Open flue to maximum. Stop using odor
causing products while log set is running.
2. Locate and correct all leaks (see
Checking Gas Connections, page 11).
1. Locate and correct all leaks (see
Checking Gas Connections, page 11).
2. Replace control valve.
1. Locate and correct all leaks (see
Checking Gas Connections, page 11).
1. Bleed gas lines.
2. Turn control to full Open position.
3. Replace gas supply line.
21