Allow for sufficient access space for pump maintenance and make sure that the technical plate of
the pump is visible.
During the installation of the pump, position it so there is 1 meter of free space around it.
ELECTRICITY
Place the motor on the floor before connecting it to the mains. Otherwise, the motor could cause a
serious and even mortal electric shock. Do not place it on the floor over a gas pipe.
To avoid a dangerous or mortal electric shock, disconnect the power supply of the motor before
working on the electrical connections.
If it short-circuits, this will indicate there is an electricity problem. If it short-circuits and cannot be
restarted, ask a qualified electrician to verify and repair the electrical system.
The pump should be powered from an insulated transformer or via a circuit breaker or
residual-current device of 30mA maximum.
The power supply should exactly correspond to the voltage indicated on the plate of the
motor. Incorrect voltage could provoke a fire and/or damage the motor, and would
cancel the guarantee. In case of doubt, check with an electrician.
The electric cable is included and comes with a "Y" connection. If it is necessary to replace the
electricity cable, the new cable should also be of the appropriate type. The guarantee will be
cancelled in the case of any unauthorised modification of the components.
The electrical installation has to be according to current legislation.
If the electrical cable is damaged, the manufacturer, its agent, or any other qualified person should
replace it to avoid any damage.
The pump is equipped with complete thermal protection. Follow the assembly diagram below for
correct electrical installation.
The electrical installation should be done by someone qualified in working with electrical equipment.
This equipment is not designed for those with physical, sensory or mental handicap or people
lacking in experience, unless done under supervision or with instructions of use from a person in
charge of safety.
Do not permit children nor adults to sit or lean on the equipment. Children should be supervised to
ensure that they do not play with the equipment.
Adjust the value of the thermal relay appropriately depending on the pump current.
Unsuitable mains connections involve the risk of electrocution
Red
Energy
Brown
Earth
connection