OPERATION
Switch the device on via the power switch. Connect the remote control with the remote control socket.
After a certain warm-up time, the device is ready to operate. When the machine is ready for fogging, the
display shows "Ready To Fog". By operating the smoke switch on the remote control the smoke emission
starts. It may happen that the stand-by lamp turns off and the smoke emission stops. In this case the device
is heating up again and will be ready to operate in approx. 1-2 min. This process guarantees an appropriate
vaporization temperature and the best smoke emission possible. The temperature is regulated by a high
quality thermostat.
The remote control's interface allows the operator to customize fog machine functions by adjusting fogging
duration, interval and volume. Its LCD displays current operating parameters, which are automatically stored
in non-volatile memory, allowing the machine to be powered down without losing function
settings.Instructions below:
down to "0". After that, the fog emission is triggered at the volume adjusted under "Timer Out". The duration
depends on the settings adjusted under "Duration Set". If you wish to deactivate the timer function, press the
Timer key once more.
Press the Volume switch for immediate triggering of the fog emission at the volume adjusted under "Volume
Out". Press the Volume switch once more in order to stop the fog emission.
Press the Manual key for immediate triggering of the fog emission at 100 % volume. Let the Manual key
loose in order to stop the fog emission.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.
Description of the elements:
(1) LCD display
(2) Function key
(3) Up/Down keys
(4) Timer key
(5) Volume switch
(6) Manual key
After the machine starts heating up, the display shows "Warming
Up". When the machine is ready for fogging, the display shows
"Ready To Fog".
Via the Function key, you can adjust the desired settings. After
pressing the Function key once, the display shows "Interval Set".
Adjust the interval between each fog emission (within the range of
1 to 255 seconds) by means of the Up/Down keys. By pressing the
Function key twice, the display shows "Duration Set". Adjust the
duration of each fog emission (within the range of 1 to 20 seconds)
by means of the Up/Down keys. Under the menus "Timer Out" and
"Volume Out" you can adjust the output volume by means of the
Up/Down keys. The menu "DMX Add" refers to adjusting the DMX
address for DMX control or synchronization. Adjust the desired
DMX-address by means of the Up/Down keys.
Press the Timer key to activate the timer function. The display
shows the adjusted interval and the device counts the seconds
21/46