Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device will be damaged, it has to be replaced by authorized dealers only in
order to avoid hazards.
If defective, please dispose of the unusable device in accordance with the current legal regulations.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
DMX control channels:
DMX512 connection:
Smoke output:
Warm-up time:
Fluid consumption:
Output volume:
Tank capacity:
Dimensions (LxWxH):
Fuse:
Weight:
Accessory:
EUROLITE Smoke fluid "B", 5L
EUROLITE Smoke fluid "C" standard, 5l
EUROLITE Smoke fluid "P" professional, 1L No. 51704209
EUROLITE Smoke fluid "P" professional, 5l
EUROLITE Smoke fluid "E" extreme, 5L
Smoke machine cleaner, 1L
Please note: Every information is subject to change without prior notice. 23.02.2011 ©
230 V AC, 50 Hz ~
1,500 W
4
3-pin XLR
approx. 8 m
approx. 10 min.
approx. 100 ml/min.
approx. 800 m³/min.
6 l
670 x 300 x 240 mm
8 A
15 kg
No. 51704199
No. 51704203
No. 51704210
No. 51704325
No. 51704592
25/46
00027459.DOC, Version 1.7

Publicidad

loading