Descargar Imprimir esta página

EAS ELECTRIC EHD10 Manual De Usuario Y Manual De Instalacion página 36

Publicidad

Idiomas disponibles

Idiomas disponibles

Silent button(On some models)
Control the fan speed. Press to select either High or
Low fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set the
fan control to Low.
Timer button(On some models)
· Press to initiate the Auto start or Auto stop feature,
in conjuction with the
unit is on, press the Timer button to activate the Auto
stop feature. When the unit is off, press this button
to activate the Auto start feature.
· Press or hold the
and
Auto time by 0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24 hours.
· The control will count down the time remaining until
start.
· The selected time will register in 5 seconds and the
system will automatically revert back to display the
previous humidity setting.
· Turning the unit ON or OFF at any time or adjusting
the timer setting to 0.0 will cancel the Auto start or
Auto stop feature.
· When LED display window displays the code of P2,
the Auto start or Auto stop feature will also be
cancelled.
UP( )/DOWN( ) buttons(On some models)
· Humidity Set Control buttons
The humidity level can be set within a range of 35%
RH(Relative Humidity) to 85%RH(Relative Humidity)
in 5% increments. For drier air , press the
and set to a lower percent value(%). For damper air,
press the
button and set a higher percent value(%).
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Auto Defrost
When forst builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
Page 14
and
buttons. When the
button to change the
button
· TIMER Set Control buttons
Use the Up/Down buttons to set the Auto start and
Auto stop time from 0.0 to 24.
Mode/
button
Press to select the operation mode:
continuously dehumidification
50% humidity level
continuously dehumidification
Display(On some models)
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0~24) while setting, then shows
the actual(±5% accuracy) room % humidity level in a
range of 30% RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes:
AS-Humidity sensor error--Unplug the unit and plug it
back in. If error repeats, call for service;
ES-Tube Temperature sensor of the evaporator error--
Unplug the unit and plug it back in. If error repeats,
call for service;
Protection Code:
P2-Bucket is full or bucket is not in right position--
Empty the bucket and replace it in the right
position.
Note: When one of the above malfunctions occurs,
turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn
off the unit and unplug the power cord. Contact the
manufacturer or its service agents or a similar qualified
person for service.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or
when the bucket is removed or not replaced in the
proper position.
For some models, the fan motor will continue to run
for 30 seconds.
V.1
40% humidity level
60% humidity level

Publicidad

loading