flue gas circulation
The device type A (see label of the device)
The devices of the type A (unrelated devices with a fireplace) must be installed in the premises well
ventilated according to standards, to prevent the accumulation of substances that can harm health in
dangerous concentrations.
Model
buzzard
burner nozzle
1/100 MM
CPASC30G
Consumption
burner nozzle
1/100 MM
CPASC60G
Consumption
INLET HOSE GAS
Determine whether the device is suitable for the type of gas used so that it complies with the instructions on
the label the type of gas used.
To convert to another type of gas, check the correspondence to the type of gas bearing.
Connecting the gas distribution must be towed to a steel or copper pipe comply with national applicable
requirements. The equipment must be checked regularly and changed if necessary.
The flexible connection between the plate and the gas system of the premises must be approved as
standards. A valve or a tap must be located upstream of the connecting hose to isolate the plate from the
gas supply.
After installation, check for possible leaks (use a suitable and approved leak detector).
The device is controlled by the manufacturer, the technical data of the device are listed on the label.
Connection to the liquid gas:
The gas pressure for the liquid connection must be 28 or 30 mbar for propane / butane and 37 mbar for
propane. It is necessary to verify the technical label for evaluating the pressure and check the nozzle
parameters which is installed with the required parameters.
If the pressure is less than 28mbar or greater than 37 mbar, the device must not be connected.
Gas Connection:
The pressure for methane connection should be 18 or 20 mbar. It is necessary to verify the technical label
for evaluating the pressure and check the nozzle settings is installed with the required parameters.
If the gas pressure is less than 18mbar to or greater than 22.5 mbar, the apparatus must not be connected.
MANUAL
Main burner ignition and regulation of the thermal power: tab. A, B
Switch the power button in the left turning on the logo "flame" and maintain the pressure piezo button until
the main burner ignites. You can see the flame in the opening of the front panel of the unit.
Tout le matériel CHR disponible sur notre site en cliquant ICI ou sur le logo et profitez des meilleurs offres et des meilleurs garanties
Tél: 09 71 04 20 23
Cliquez ici pour découvrir tout nos produits CHR
Cliquez ici pour le catalogue produits Casselin
Burner
4.0
kilowatts
4.0
kilowatts
2x 4.0
kilowatts
2x 4.0
kilowatts
Email: info@stock-direct-chr.com
12.8 kWh /
12.8 kWh /
kg
kg
G 30 / G 31
G 31
PROPAN /
PROPAN
BUTAN
37 mbar
28-30 mbar
93
93
0.546 kg /
0.546 kg / h
h
93
93
1.092 kg /
1,092kg / h
h
12.8 kWh /
9.45 kWh /
kg
m3
G 30 / G
G 20
31
GAS
PROPAN /
natural
BUTAN
20 mbar
50 mbar
77
135
0.546 kg /
0.74 m³ / h
h
77
135
1.092 kg /
1,148 m³ /
h
h
EN
Pipe joint for
gas
G 1/2 ''
---
G 1/2 ''
---