User's Manual
Introduction
Control panel for tri-phase motors at 230Vac for use in industrial sliding doors, with speed control through a variable speed drive.
Basic features: self-programming, receiver incorporated (15 codes) / pluggable receiver (433.92 (two-channel)/ 868.35 MHz), resistive safety edge inlet
(8 k2), encoder inlet (sensor hall, ...), slow-speed start of operations (programmable), slow-speed end of operations (selectable), connection to portable
programmer .
Technical data
Power supply
Power
Receiver
Optional cards
Operating temperature
Watertightness
Equipment category
Base plate size
Box dimensions
Operating
Start (START): Contact normally open to open and close. The first press opens, the second press stops (until the limit switch) and the
third closes. If it is pressed while the door is closing, it will stop and invert the operation.
Stop (STOP): Contact normally closed. This detains the operation on standby for a new order. Where not used, turn option 1 on the input
switch to ON.
The variable speed drive can cause an stop of the control panel in case of motor bad operation.
Open (OPEN): Contact normally open to open. If it is pressed while the door is closing, it will stop and open.
Close (CLOSE): Contact normally open to close. If it is pressed while the door is closing, it will stop and close.
Security contact (SEC.CL): Contact normally closed, photocell or magnetic detector type. This acts on closing, causing stoppage and
inversion. Where not used, turn option 2 on the input switch to ON.
Security edges (S.EDGE): Resistive contact for resistive security edge. This acts on closing, causing stoppage and inversion. Where not
used, turn option 3 on the input switch to ON.
Where option 6 of the options switch is turned to ON, the band is inhibited during the last 4 cm of door closure.
Ends of run (FC.CL / FC. OP): contacts normally closed to mechanically indicate the open and closed end of run. For operation by time,
it is necessary to have it installed. For operation by pulses, at least one of them should be installed. Where not used, turn option 4 or 5
on the input switch to ON.
Encoder inlet (+, S.H., -): Allows for an NPN-type encoder (or sensor hall) to be connected at 5Vdc, necessary for the operation by
pulses.
Reference search function: If the panel loses power halfway through the operation, on receiving power it goes into reference search
mode, in such a way that the door will move until a mechanical stop or the end of the run is reached, with preference given to the
opening reference, if it exists. Reference search is indicated by the corresponding flashing of the SAFETY light (see table).
The Aut ref Search parameter (configurable by means of programmer) is selected if the user requires this automatic search or wishes to
wait for the START button to be pressed for the reference search.
N.B.: The panel may lose the reference if the power is disconnected halfway through the operation.
Door operation control function with external clock: By connecting an external clock or timer (normally open) between the common
push button terminal (16) and the bridged Open and Close terminals (17 and 18), it is possible to temporize the opening and closing of
the door.
OPTIONS SWITCH
Option No.
1 (AUTO PROG)
2 (AUTO CLOSE.)
3- NON STOP ON OPENING
4 (SLOW)
5 (BRAKE)
6 (INH.SEC.EDGE 4 cm)
7 (DEAD MAN)
INPUTS SWITCH
Option No.
Upper position – ON (default option)
1 (STOP)
Stop button not connected
2 (SEC.CL.)
Security Close contact not connected
3 (S.EDGE )
Security band not connected
4 (FC.CL.)
End of run close not connected
5 (FC.OP.)
End of run open not connected
UM_3200436_VAR-R15_5ID_Rev01
230V
0,75 KW
868,35MHz incorporated 15 codes
Pluggable receiver card (433,92 (bi-channel) / 868,35 MHz)
-10ºC to +40ºC
IP56
Class II
160x83x27 mm
300x220x180mm
Upper position – ON
Self-programming
Automatic closure
Does not allow for radio reverse on opening
Allows for slow speed (default option)
12Vdc motor brake output
Inhibits the security edge for the last 4 cm of the run
Dead-man operations
Lower position - OFF
Manual programming (default option)
Does not close automatically (default option)
Allows for radio reverse on opening (default option)
Does not allow for slow speed
Without function
Does not inhibit the security edge (default option)
Semi-automatic or automatic operations (default option)
Lower position - OFF
Stop button connected
Security Close contact connected
Security edge connected
End of run close connected
End of run open connected