Descargar Imprimir esta página

Trilux LIVELINK Instrucciones De Montaje página 4

Ocultar thumbs Ver también para LIVELINK:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
LIGHTGRID TOUCHPANEL
EN
Important information on electronic control gear
units (ECG)
A neutral conductor interruption in the three-phase
circuit leads to overvoltage damage in the lighting sys-
tem. Only open the neutral conductor isolating terminal
in de-energised state, and close the neutral conductor
isolating terminal before switching on again. Do not
exceed the maximum permissible ambient temperature
ta of the luminaire.
Exceeding this limit reduces the service life and in
extreme cases there is a risk of premature failure of the
luminaire. Design connection cables for the control
inputs of DALI control gear (1-10 V, DALI etc.) to be
230 V mains voltage-proof (basic insulation).
Disposal of waste electrical and electronic equipment
Always collect and dispose of old electrical
and electronic equipment separately at the
end of its service life. In case of doubt, seek
information about environmentally-compliant waste
disposal from your local district authority or special
waste disposal companies. Current information on the
energy efficiency class of the selected product version
can be found in the corresponding data sheet for the
luminaire. Instructions for replacing or removing the
light source in accordance with Regulation 2019/2020/
EU can be found at:
www.trilux.com/EcoDesign
Directive 2014/53/EU
Simplified EU Declaration of Conformity according
to the RED Directive if the luminaire is equipped
with a control gear unit with NFC interface or a radio
component:
TRILUX hereby declares that the following radio sys-
tem type complies with Directive 2014/53/EU:
...
LIVELINK
The full text of the EU Declaration of Conformity is
available on the Internet at:
www.trilux.com/eu-conformity
6 | 32
10262845 | 220610 | © trilux.com
LIGHTGRID TOUCHPANEL
TECHNICAL DATA (TOUCHPANEL)
Input voltage
Input current (nominal)
Battery
Ambient temperature ta
Humidity
Radio technology
Transmission frequency
TECHNICAL DATA (POWER SUPPLY UNIT)
Input voltage
Input frequency
Output voltage
Output current
Nominal power
Ambient temperature ta
Relative humidity
(without condensation)
Service life
Standards
© trilux.com | 220610 |10262845
EN
9-24VDC SELV
max. 30mA
CR1632
-20 ... +45°C
1% to 90% r.h.
non-condensing
Bluetooth
2480 MHz
220-240 VAC
50 / 60 Hz
12 VDC
0,5A
6 W
-10 ... +50°C
5 % ÷ 90 %
~ 120'000 h
EN60950
EN55022/B -
EN61000-4
7 | 32