Descargar Imprimir esta página

Procom Heating MG10HBF Manual De Instrucciones página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term "qualified agency" means any
individual, firm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with a piezo ignitor.
this system requires no matches, batteries, or
other sources to light heater.
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free op-
eration. State and local codes in some areas
prohibit the use of vent-free heaters.
200310-01C
QUALIFIED INSTALLING AGENCY
PRODUCT FEATURES
LOCAL CODES
www.usaprocom.com
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
Propane or Natural gas. The heater is shipped
from the factory ready for connecting to Pro-
pane. The heater can easily be changed to
Natural gas by having your qualified installer
follow the instructions on page 13 and the
markings on the heater.
State of Massachusetts: The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a flexible
appliance connector cannot exceed three
feet in length.
5

Publicidad

loading