Cleaning the water tank of the Clean Air Optima® Air Cooler
1. Switch off the device and pull the plug. During cleaning and descaling, the device must not
be used.
2. Unlock the water tank by turning the two clips from the vertical position to the horizontal
position.
3. Pull the water tank halfway out of the appliance.
4. Turn the water pump handle from the vertical to the horizontal position, see the schematic
diagram below for disassembling and assembling the water pump.
5. Slide the waterpump out of the bracket,
see the schematic diagram here on the left.
6. Clean the inside of the water tank with
Clean Air Optima® Cleaner & Descaler and rinse
with clean water. Pour two capfuls of Clean Air
Optima® Cleaner & Descaler into the water tank
and leave for between two and five minutes.
Then add water up to the rim of the watertank and
leave for a minimum of 30 and a maximum of 60
minutes.
Rinse the watertank thoroughly with water.
7. Remove any splashes of Clean Air Optima®
Cleaner & Descaler from work surfaces or the
outside of the device with a soft, damp cloth.
After cleaning and descaling, your device is hygienically clean, free of limescale, free of bacte-
ria, free of viruses and immediately ready for use again.
Please note: