Descargar Imprimir esta página

RSG 400 Serie Instrucciones De Uso página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
RSG Full Mask User Manual June 2012aw :Layout 1 12/06/2012 13:39 Page 9
5. REPLACING THE SPEECH MEMBRANE:
The mask's inner mask can be removed by pulling gently. The screw ring can be
screwed out and the speech membrane's cover removed. Then take out the membrane
and the O-ring. A new O-ring and membrane can then be fitted. The cover and screw
ring are mounted once again and the inner mask refitted. After replacement of the
speech membrane, a leakage test must be carried out using a suitable leakage analyser.
6. REPLACING THE VALVE HOUSING (COMPLETE):
The mask's inner mask can be removed by pulling it gently. The closing band can be
loosened with a screwdriver and removed. "Support for valve housing" can be removed
from the visor frame and the complete valve housing can be pulled out of the body of
the mask. A new original valve housing can be put in place, "support for valve housing"
fitted onto the visor frame, and finally the closing band can be refitted and tightened
properly. After replacement of the complete valve housing, a leakage test must be
carried out using a suitable leakage analyser
TABLE 1.
CONSTRUCTION PARTS (FIG. 1):
Pos Name
1
Mask body
2
Button
3
Visor
4
Visor frame
5
Screw for visor frame
6
Inner mask
7
Valve membrane
8
Valve
9
Supp. f. valve housing
M INTEN CE - T BLES
Pos Name
10
Screw ring
11
Cover 1 (speech membrane)
12
Speech membrane
13
O-ring
14
Cover 2 (speech membrane)
15
Valve housing
16
Outlet valve membrane
17
Inlet valve membrane
18
Inlet valve pin
(GB) 8
Pos Name
19
Inlet valve seat
20
Cover (valve housing)
21
Closing band
22
Screw for closing band
23
Head harness
24
Roller
25
Buckle
26
Carrying strap
27
Buckle (carrying strap)
copyright 2018 ©

Publicidad

loading

Este manual también es adecuado para: