Installation (continued)
SECURING THE FAN TO THE CEILING JOIST
UNFINISHED CEILINGS
NOTE:
Ensure your fan is properly connected to the duct work and electrical
supply cable (not powered) before proceeding.
- Secure the ventilation fan to the ceiling joist in a desired
location using the external mounting tabs . The fan housing
should be installed below the joist surface such that it is flush
with the ceiling surface once it is installed. See figure 15.
- Reinstall motor mounting assembly . Plug the motor into the
receptacle. See figure 16.
- Power the fan to make sure everything is in proper working
order .
- Once you are satisfied with your installation, protect the bath
fan motor from construction dust and debris with the supplied
dust cover (D) until construction is completed. See figure 17.
Do not install the dust cover in finished construction. Do not
operate the fan with the dust cover in place as it will damage
the motor .
INSTALLING THE GRILLE
- Squeeze the springs on the grille together, and insert the
springs into the slots of the housing assembly . Firmly push
the grille up against the ceiling. See figure 18.
Drywall
thickness
Ceiling
11
Please contact cs@conglomkb.com or 1-877-333-0098 for further assistance .
Joist
Fig . 15
Fig . 16
Dust cover (D)
Fig . 17
Spring slot
Fig . 18