3. Turn on or plug in the power supply to the hot water dispenser.
The unit fills at the approximate rate of 1 gallon (3.8 L) per
minute, depending on water line pressure.
4. Heat and discard at least one tank of water.
DEFAULT SETTINGS
• Temperature: 150°F/65°C
• Unit of measurement for temperature: Fahrenheit
• Water connection: Plumbed into water supply
• Night mode temperature: fixed at 158°F (70°C)
OPERATING INSTRUCTIONS
SETTING THE TEMPERATURE
1. Press
2. Use the
3. Once desired temperature is displayed, press the
to set or wait 10 seconds to set new temperature.
4. Display will show set temperature and PRESS START blinking.
5. Press
CAUTION: Water is very hot. Use caution when pouring or
transporting hot water. Accidental spills may result in severe burns.
SETTING °F/°C
1. Press
2. Once in program mode, PRESS and HOLD the
for 2 seconds.
3. Use the
4. Once desired unit of measure is selected, press
to set.
5. If neither button is pressed for 15 seconds, then the F or C
displayed will be programmed.
SETTING THE CLOCK
1. To set the clock, press and hold the
2 seconds.
2. Use the
3. Once the desired time is displayed, wait 10 seconds, and the
time will be set. Display will show set time for 3 seconds.
button once.
arrows to reach your desired temperature.
to begin filling and heating water.
button once.
arrows to switch from F to C.
arrows to scroll.
button for
9
button
button
twice

Publicidad