5.3
Charging Batteries in Vehicles
1.
Make sure the battery charger is not yet connected to the mains.
Connect the charger to the vehicle's battery. Stay clear of fan
2.
blades, belts, pulleys and other parts that can cause injury to
persons. Determine which battery terminal is grounded to the
chassis.
o Negative terminal is grounded: Clamp the positive terminal
clamp (red) of the charger to the positive terminal on the
battery. Then, clamp the negative terminal clamp (black) of the
charger to the chassis or engine block, away from the battery.
Do not connect to the carburettor, fuel lines or sheet metal
body parts.
o Positive terminal is grounded: Clamp the negative terminal
clamp (black) of the charger to the negative terminal on the
battery. Then, clamp the positive terminal clamp (red) of the
charger to the chassis or engine block, away from the battery.
Do not connect to the carburettor, fuel lines or sheet metal
body parts.
3.
Connect the power cable of the battery charger to the mains.
4.
When disconnecting, disconnect from the mains first, remove
the grounded clamp and then remove the clamp connected to
the battery.
6.
Cleaning and Maintenance
 The device is maintenance-free.
 Under no circumstances should solvents or other aggressive
cleaning agents be used.
 Clean the plastic surfaces of the device with a soft and dry cloth.
7.
Technical Specifications
rated input voltage ..................... 110-240 V~, 50/60 Hz
rated output current ........................... 12 VDC, 800 mA
dimensions ...................................... 60 x 120 x 37 mm
V. 01 – 21/08/2017