Descargar Imprimir esta página

edenox VIVES-5 HC Manual De Utilización página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

Fault
The appliance turns on, but
the temperature is too high/
low
The appliance is leaking
water
The appliance is unusually
loud
The display lamp does not
illuminate
Door does not shut
Technical Specifications
Model
Voltage
Power
VIVES-5 HC 230V 50Hz
160W
VIVES-7 HC 230V 50Hz
160W
VIVES-9 HC 230V 50Hz
170W
Probable Cause
Too much ice on the condenser
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat
source, in the direct sunlight
or air flow to the condenser is
being interrupted
Ambient temperature is too
high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
Factory default parameters
adjusted
The appliance is not properly
levelled
Loose screw/nut
The appliance has not been
installed in a level or stable
position
Lamp needs replacing
Light not turned On
Dirt/obstacle in runners
Current
Range
1.0A
3°C to 8°C
1.0A
3°C to 8°C
1.0A
3°C to 8°C
5
Action Required
Defrost the appliance
Call or qualified technician
Check doors are shut and seals are
not damaged
Move the refrigerator to a more suit-
able location
Increase ventilation or move appliance
to a cooler position
Remove any excessive hot foodstuffs
or blockages to fan
Reduce the amount of food stored in
the appliance
Call or qualified technician
Adjust the screw feet to level the ap-
pliance (if applicable)
Check and tighten all nuts and screws
Check installation position and change
if necessary
Call or qualified technician
Ensure Light button has been pressed
properly
Clean runners
Refrigerant
(litres)
70
R600a 45g
94
R600a 45g
117
R600a 50g
UK
H x W x D (mm)
(kg)
428 x 386 x 850
30
428 x 386 x 1000
36
428 x 386 x 1150
81

Publicidad

loading

Este manual también es adecuado para:

Vives-7 hcVives-9 hc