General safety precautions
This installation manual is intended for qualified personnel only.
ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to improper use or any use
other than the intended usage indicated in this manual.
Installation, electrical connections and adjustments must be performed by qualified personnel, in accordance
with best practices and in compliance with applicable regulations.
Before installing the product, make sure it is in perfect condition
Disconnect the mains electrical power before performing any work. Also disconnect any buffer batteries used.
Only use original spare parts when repairing or replacing products.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within
reach of children, as they are a potential source of danger.
WARNING! Handle electronic parts and terminals with extreme care, as these parts are highly sensitive to
static electricity.
2
Technical specifications
TECHNOLOGY USED
MAINS POWER VOLTAGE
CURRENT ABSORPTION
INFRARED BEAM WAVELENGTH
LED EMISSION ANGLE
MAXIMUM OPERATING RANGE
MINIMUM OPERATING RANGE
OUTPUT CONTACT
SYNCHRONISM
RELAY TRIGGER TIME
RELAY RELEASE TIME
OPERATING TEMPERATURE
DEGREE OF PROTECTION
DIMENSIONS G90/F4ESI
WEIGHT
3
Product description
The G90/F4ESI synchronised photocells for flush-mounting installation are infra-red movement detector devices.
4
Electrical connections
TRANSMITTER TX
1(+24V)
2-COM (0V) Power supply 24VAC-DC.
3(SYNC)
RECEIVER RX
1(+24V)
2-COM (0V) Power supply 24VAC-DC.
3 /4 (N.C.)
5(SYNC)
8
Active infrared, with modulated transmission controlled by a
microcontroller
24 Vac / Vdc
TX= 18 mA, RX= 27 mA
860 nm
±10°
15 m
0,8 m
Double relays with contacts in series (double safety), normally closed
contact, 30 V max 0.5 A max with resistive load
digital with wired connection
<30 ms
<100 ms
-20°C
IP55
mm 75x77x80,7
167 gr
DESCRIPTION
Synchronism terminal SYNC. Connect the 3-SYNC terminal of the transmitter
photocell to the 5-SYNC terminal of the receiver photocell.
DESCRIPTION
N.C. contact. Photocell connection output.
Synchronism terminal SYNC. Connect the 5-SYNC terminal of the receiver
photocell to the 3-SYNC terminal of the transmitter photocell.
+55°C