INSTALLATION INSTRUCTIONS
STEP 1
Rooflight Model
00-97000i, 00-97100i
00-97010i, 00-97110i
Refer to the above table for roof size opening. If you are
replacing another type already installed, remove the old
existing roof vent. Remove all old roof sealant for a minimum of
5 cm (2 inches) entirely around the roof opening.
STEP 2
Measure the thickness of the roof opening. NOTE: For curved
roofs, measure the thickest part of the roof.
Rooflight Model 00-97100i & 00-97110i
VEHICLE ROOF
THICKNESS
23 – 30 mm
30 – 35 mm
35 – 42 mm
Rooflight Model 00-97000i & 00-97010i
VEHICLE ROOF
THICKNESS
42 – 48 mm
48 – 54 mm
54 - 60 mm
STEP 3
Prior to installing the SKYMAXX ROOFLIGHT over the roof
opening, apply a continuous strip of butyl tape or equivalent to
the underside of the flange in the grooved space.
CAUTION!
When installing your MAXXAIR ROOFLIGHT,
only use a caulking/sealant compatible with the flange (plastic
product) and the roof surface. DO NOT use materials
containing solvents such as or similar to Xylene, Toluene,
Methyl Ethyl Ketone (MEK), Acetate or Acetone as they can
damage the flange. Also, Polysulfide (Thiokol) type sealants
must be avoided.
If in doubt, please contact the manufacturer of your caravan
for further information.
STEP 4
Insert the SKYMAXX ROOFLIGHT into the roof opening with
the hinged section facing the front of the vehicle with the ceiling
flange centered in the opening. Press down on the flange to
compress the BUTYL sealant to seal to the roof.
STEP 5
After the MAXXAIR ROOFLIGHT has been installed, remove
the excess BUTYL caulk that may have squeezed out. Using a
sealer such as Dicor self-leveling lap sealant or similar
caulking, apply a bead (approximately 5 mm dia.) along the
outside edge of the flange all the way around the rooflight.
THIS COMPLETES THE ROOF TOP PORTION OF THE INSTALLATION
Roof Opening
700 mm x 500 mm
LENGTH OF
SCREW
24 mm
30 mm
36 mm
LENGTH OF
SCREW
42 mm
48 mm
54 mm
Skip to page 4 for interior installation of SKYMAXX LX Plus