Descargar Imprimir esta página

BriskHeat BH-610 Manual De Instrucciones página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Now, switch on the operating voltage of the unit by pressing the arrow keys.
Setup
Enter the Setup menu and set the Values for lower / upper limit and range. Choose the desired temper-
ature sensor. See also chapter 5 Set-up Menu on page 7
3
General information
The BH-510 & BH-610 is a compact, feature rich, intuitive FAT Temperature Controller for wall-
mounting. FAT stands for Fast-Adaptive-Tuning. A novel algorithm permanently adjusts the control
parameters to the control process. The common adjustment of PID controllers or the execution of an
auto tuning proce-dure is obsolete.
The self-optimizing controller logic leads to an efficient adaption to any closed-loop controlled pass and
quickly reaching adjustment between set-point temperature and actual (temperature) value.
All functions are shown inside the display and can be easily reached and set via the buttons on the
control panel.
The BH-510 & BH-610 is equipped with a long-life Hybrid-Relay designed for low thermal losses inside
the hous-ing. An additional Safety-Relay underlines the high standard in terms of safety and efficiency
of the BH-510.
A multi-colored LED is signaling the different operating modes, easy viewable in the distance.
The electronics is protected against overcurrent and high thermal load.
4
Control panel
4.1
Overview of functions
Enter set up menu: simultaneous pressing Enter Button


Change Set-Point Temperature: Press (hold) Up
Failure notes can be reset by pressing enter button


Controller On/ Off: simultaneous pressing Up Button
4.2
Standard display information
Set-point temperature:
Temperature maintained by the controller
Actual temperature measured by connected temperature sensor
Actual (temperature) value:
Thermometer Icon informs:
Temperature above
BH-510 Heater-Icon
tolerance at set-point temperature
visible:
Heater on
BH-610:
Around the set-point temperature
Heater-icon:
The Icon
This happens during startup or on changed set point
temperature.
During continuous operation filled triangle
needed power.
®
© BriskHeat
Corporation
BH-510 & BH-610 Operation
Manual
Display  
Up  / Down  
Bu ons  
Status LED   
Enter Bu on   
Back Bu on  
and Back Button
or Down
Button
and Down Button
for several seconds
/ beneath
/ in between
range of
shows detection of needed power is in progress.
shows the
®
. All rights reserved.
5
4.3
Status monitor (3-color-LED)
After connecting to power supply, the controller starts with a self-test: white LED on for 1 sec. Self-test
successfully completed and controller starts heating: green LED on for 0.3 sec.
If a failure would be detected a default signal will show up: see 4.4 Fault Detection.
The heat-up phase continuous until the set-point temperature has been reached: blue LED on/off with a
frequency of 1 Hz
Set-point temperature reached:
The Controller works at set-point temperature inside the tolerance-band set by the user: green LED
permanent on
Temperature monitor:
The temperature during operation, is permanently under control. The LED remains green at set-point
temperature in-between the band of tolerance. Above and below this temperature range the LED starts
to blink with a frequency of 1Hz. Blue signals too low and red too high temperatures.
4.4
Fault detection
From start and during operation the controller is permanently checking PCB temperature, power sup-
ply, sensor break and failure of the relays. If any failure occurs the controller stops heating (stand-by)
Additionally the error occurs in the display. Failure notes can be reset by pressing enter button
the failure note cannot be reset by this procedure, the occurring problem has to be solved and the
controller reconnected to power supply to restart the controller.
Fast blinking signal of failures with a frequency of 4 Hz.
1.
Device failure:
2.
Sensor failure
®
© BriskHeat
Corporation
BH-510 & BH-610 Operation
Manual
. If
®
. All rights reserved.
6

Publicidad

loading

Este manual también es adecuado para:

Bh-510