Troubleshooting
Symptom: The fan does not run.
• Check for an open fuse or circuit breaker in the building's
service panel.
• Check that the plug-in connection for the Motor is seated
firmly in place.
• Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically.
• Check that the Blower Wheel is firmly attached to the
Motor shaft and both spin freely.
Symptom: The fan seems noisy.
• Check that the back draft damper in the fan's Transition
pivots freely.
• Check that the back draft damper in the wall or roof cap
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris.
Service Parts
7
Order replacement
parts by Part No.,
not by Key No.
Key No. Part No.
1
97018349
2
97018721
3
97018382
4
97018448
5
97019521
97019522
6
97019520
7
97019466
8
97018533
9
99140208
10
99111400
11
99271381