2 - INTRODUCING THE PRODUCT
2.1 - Technical characteristics
TECHNICAL SPECIFICATIONS
Torque
Temporary service
Opening time
Control unit
Power supply
Motor absorption
Input power
Integrated lights
Protection class
Dimensions (L-P-H)
Weight
Operating temperature
Maximum length of rod
* with 8 m bar
3 - PRELIMINARY CHECKS
Before installing the product, perform the following checks and in-
spections:
check that the barrier is suitable for automation;
the weight and size of the barrier must be within the operating limits
specified for the automation system in which the product is installed;
check that the barrier has firm, effective mechanical safety stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the pro-
duct to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide tempe-
rature variations or high temperatures), friction may increase, cau-
sing a corresponding rise in the force needed to operate the system;
10
900ALT424
900ALT624
200 Nm
250 Nm
80 %
3,5 sec
6/*12 sec
CT10224
CT10224
Vac (Vdc) 230 (24)
Vac (Vdc) 230 (24)
1,3 A
300 W
-
IP 54
320-220-1000 mm
400-280-1051 mm
46 Kg
-20 °C + 55 °C
-20 °C + 55 °C
4 m
6*(8 mt)
the starting torque may therefore exceed that required in normal
conditions;
check that when operated by hand the barrier moves smoothly wi-
thout any areas of greater friction or derailment risk;
check that the barrier is well balanced and will therefore remain sta-
tionery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and dif-
ferential safety breaker device;
the system power supply line must include a circuit breaker device
with a contact gap allowing complete disconnection in the condi-
tions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.
900ALT242K
200 Nm
80 %
80 %
3,5 sec
CT10224
Vac (Vdc) 230 (24)
1,3 A
1,3 A
300 W
300 W
-
yes
IP 54
IP 54
360-220-1110 mm
66 Kg
47 Kg
-20 °C + 55 °C
4 m
900ALT624K
250 Nm
80 %
6/*12 sec
CT10224
Vac (Vdc) 230 (24)
1,3 A
300 W
yes
IP 54
450-280-1188 mm
67 Kg
-20 °C + 55 °C
6*(8 mt)

Publicidad

loading

Este manual también es adecuado para:

Alt 6 serie900alt424900alt624900alt242k900alt624k