This section provides a list of the more frequently encountered malfunctions, their cause and corrective actions. The operator or maintenance personnel can
perform some corrective actions, and others may require the assistance of a qualified D
Defective Pattern
likely cause
Material leaking
1. Loose cup or
from fluid inlet
foreign substances
of cup.
on/ between cup
thread and fluid inlet
Material leaking
1. Worn fluid needle
from nozzle when
2. Dried material in tip
trigger is released
of nozzle
3. Loose packing nut
Dried material is
A.
clogging side-port "A"
and causing
side-port "B" to blow
spray towards the
clogged side
B.
1. Dried material at
fluid nozzle "C"
restricts air flow
2. Loose air nozzle
3. Air pressure
set too high
TROUBLESHOOTING GUIDE
Suggested remedy
1. Tighten and clean
or replace it
1. Replace
2. Clean
3. Tighten needle
packing nut by turning
counterclockwise
Soak side-ports in
A
thinner to clean clog.
Do noT poke any
opening with hard objects.
B
C
1. Remove air nozzle.
Wipe off fluid tip using a
cloth soaked in thinner
or by soft brush
2. Fasten nozzle securely
3. Reduce air pressure
WalT technician or your dealer.