SmartWash
Operating Manual
Your SmartWasher is shipped fully assembled. (The OzzyMat
support grid and false bottom of the sink are packed inside the sink).
Visually inspect for damage (minor scratches and scuffs are normal
due to the molding process).
Remove the false bottom and check to make sure the mat support grid
is in the bottom of the sink. Remove and discard packing material.
The SmartWasher
when it is filled with fluid. It should be installed close enough to a
normal 115VAC (220VAC) Ground Fault Circuit Interrupter (GFCI)
electrical outlet so that it can be plugged in. The SmartWasher
should be the only item plugged into this circuit. Do not plug in
before adding fluid.
PARTS WASHER SETUP
1. Remove the OzzyMat from its package, unfold it and lay it on
the mat support grid located in the lowest level in the sink.
Make sure to lay the OzzyMat white side up.
2. Place the false bottom in position in the sink.
3. Form the flexible nozzle to its desired shape and be sure
that the parts brush is inside the sink.
4. At start up, carefully add 25 gallons (five 5-gallon boxes) of
OzzyJuice
solution directly into the sink.
5. Plug the unit in to a 115V (220VAC) GFCI electrical outlet.
6. The SmartWasher will take approximately four hours to heat
up to its selected optimal temperature of 108°F (+-2°)
(42°C)(+-1°)
temperature will be maintained as long as the SmartWasher
is plugged in and full of OzzyJuice. (If the low fluid light is on,
the heater automatically shuts off.)
PARTS WASHER OPERATION
1. The pump switch is attached to a ten or thirty minute timer.
Turning the switch ON (upward position) will start fluid flowing
for ten or thirty minutes. To restart the flow, turn the switch OFF
then ON again and the flow will restart for another ten or thirty
minutes.
2.
Adjust the valve at the base of the faucet to control the flow
of the fluid through the faucet. The valve at the base of the
brush hose controls the flow of fluid through the brush. Both
outlets can be operated independently or together.
CHECK LOCAL REGULATIONS:
1
ChemFree Technical Support : 800-521-7182 www.chemfree.com
r e
®
Ozzy
®
will weigh approximately 300 pounds (136 Kg)
®
FALSE BOTTOM
OZZYMAT™
MAT SUPPORT GRID
to the SmartWasher by slowly pouring the
®
OR
115°
F(+-2°)
You may be able to dispose of your used OzzyMat as solid waste or with your other absorbent mats.
INSTALLATION AND SETUP
,
(46°C)(+-1°).
This
IMPORTANT MAINTENANCE NOTICE
The OzzyMat should be changed at least
every 30 days or the Ozzy microbes will
lose their effectiveness!
OZZYMAT – FL-3 / FL-4
The OzzyMat traps sludge and dirt as
small as 50 microns. It works
effectively even when it appears dirty.
At some point, however, it will become
saturated and unable to pass fluid
freely and should be changed. The
SmartWasher has bypass openings
located under the false bottom of the
sink to accommodate overflow when
the OzzyMat is clogged. The FL-4
Multilayer OzzyMat allows you the
benefit of being able to peel layers
between mat changes.
FL-4 MAINTENANCE
1.
Make sure the pump is not
running.
2.
Lift out the false bottom of the
sink and lean to one side.
3. Remove the top (peelable) layer
of the OzzyMat, wring excess
fluid back onto OzzyMat in sink
and dispose of according to local
regulations.
4. Return the false bottom to its
proper position.
REPLACING THE OZZYMAT
(Should be done every 4 weeks!)
1.
Make sure the pump is not
running.
Lift out the false bottom of the
2.
sink and lean to one side.
3.
Remove the soiled OzzyMat.
4.
Remove a new OzzyMat from its
poly bag, unfold it and lay it on
top of the mat support grid with
the white side up.
5.
Wring excess fluid on to new
OzzyMat. It is important to wring
used OzzyMat prior to disposal.
6.
Place used OzzyMat into the poly
bag the new mat came in.
7.
Replace false bottom in sink.
8.
Discard OzzyMat in accordance
with local regulations.