English
Application
Camera 130/180 for Siedle Classic.
Available for the systems In-Home
bus, Access or as a system-free
camera.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
1 In the case of video systems, the
following mounting situation must
be avoided at all costs:
• direct backlight
• direct sunlight
• very bright image backgrounds
• highly reflective walls opposite the
camera
• lamps or direct light sources
Mounting
2 Recommended mounting height
appr. 1.60 m to centre camera.
3 Pick-up angle of the camera with
an angle of aperture of appr. 130°.
4 Pick-up angle of the camera with
an angle of aperture of appr. 175° in
the full screen mode.
5 With an angle of aperture of
appr. 175°, the pick-up angle of
the camera can be adjusted to any
mounting situation. Open the flap
on the back of the module with the
aid of a screwdriver.
6 Set the required picture excerpt
from the camera view (1 to 9) or full
screen (0) using the rotary switch.
Once the required picture excerpt
has been set, close the flap and
mount the module.
6
7 Select the picture excerpt based
on the existing mounting situation.
The camera's pick-up angle is thus
reduced.
a Picture excerpt (1–3)
top camera alignment
b Picture excerpt (4–6)
central camera alignment
c Picture excerpt (7–9)
bottom camera alignment
Terminal assignment
CBCM 653-.../658-...
TaK
In-Home bus
TbK
camera branch
Ta
In-Home bus
Tb
Vc
Camera actuation
GND
b
Power supply 12 V AC
c
CACM 673-.../678-...
V1
Video signal (two-wire FBAS)
V2
V3
Camera supply
V4
V5
Actuation of video output
V6
CCM 613-.../618-...
+M
Supply voltage
-M
10–50 V DC
Vc
Camera actuation
-
VKA Actuation of
camera distributor
A1
Potential-free contact
A1
b
Power supply 12 V AC
c
L/S
Coaxial connection
L = lead, S = shield
Installation
Installation, commissioning and pro-
gramming are described in the rel-
evant system manual and enclosed
with the line rectifier/server.
Servicing
If a camera has to be exchanged,
this is unplugged at the terminal
block and replaced.