Descargar Imprimir esta página

Dustcontrol 94178-B Manual Original página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Description DC AirCube 500
The DC AirCube 500 aircleaner is intended for
cleaning the air in a work area and is intended for
use as a compliment to spot extraction. Air is pas-
sed through a combination prefi lter and a micro-
fi lter. The microfi lter is a HEPA 13 fi lter separates
particles to 99.95%. The pre- fi lter separates the
majority of the course particles and thereby pro-
longing the life of the microfi lter.
When a loss of suction capacity is experienced the
pre-fi lter should be changed. If the suction capa-
city does not increase after the pre-fi lter change
then the Hepa fi lter should also be changed.
NOTE: When using a long tube or covering the
outlet, the warning light (fi lter light) can be lit.
Check when changing the fi lter that the outlet is
free (warning
light).
Operation
Connect the machine to a suitable power source
according to the specifi cation of the machine.
When using an extension cable with the machine,
ensure that the connection is water tight and the
extension cable is suitably rated.
The fan has two speed settings which allow for
economical running, for example during the night.
The DC AirCube 500 can also be used to dischar-
ge air from work places which must be kept under
negative pressure. A 125 mm hose can be at-
tached to the fan outlet where necessary.
Optinal power outlet 240 V 1200 W.
The DC AirCube aircleaner has two speed settings
which allows for economical running, for example
during the night.
DC AirCube - 15
Part No 94178-B

Publicidad

loading