COLD WEATHER CARE
Do not store the Stapler in a cold weather
environment.
Keep the Stapler in a warm area until beginning the
work.
If the Stapler is already cold, bring it in a warm area
and allow the Stapler to warm up before use.
1 Reduce the air pressure to 40 psi (2.8 bar 2.8 kgf/
2
cm
).
2 Remove all staples from the Stapler.
3 Connect the air hose and free-fire (blank-fire) the
Stapler.
The lowered air pressure will be enough to free-
fire the Stapler.
Slow speed operation tends to warm up the
moving part.
CAUTION
Do not free-fire the Stapler at high pressure.
TESTING THE STAPLER
DANGER
WARNING
Never use Stapler unless push lever is operating
properly.
Before actually beginning the stapling work, test the
Stapler by using the checklist below. Conduct the tests in
the following order.
If abnormal operation occurs, stop using the Stapler and
contact a Hitachi authorized service center immediately.
(1) DISCONNECT AIR HOSE FROM STAPLER.
REMOVE ALL STAPLES FROM STAPLER.
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
Operators and others in
work area MUST wear
safety glasses with side
shields which conforms
to ANSI Z87.1
specifications.
— 10 —
THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Trigger
Push
Lever
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
Do not load any staples in the Stapler.
THE STAPLER MUST NOT LEAK AIR.
Hold the Stapler downward and pull the trigger.
THE STAPLER MUST NOT OPERATE.
Pull Trigger
Push
Lever
(3) With finger off the trigger, depress the push lever
against the workpiece.
THE STAPLER MUST NOT OPERATE.
Do not pull Trigger
Depress
Push Lever
(4) Without touching the trigger, depress the push lever
against the workpiece.
Pull the trigger.
Do not connect
air hose
2
).