REGULATED PRESSURE GAUGE
The outlet pressure gauge (C) indicates the air pressure available at the outlet side of the regula-
tor. This pressure is controlled by the regulator.
REGULATOR
The regulator (D) controls the air pressure shown on the Regulated Pressure Gauge (C). Pull the
knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure.
When the desired pressure is reached push knob in to lock in place. The regulated pressure
range is 7–150 psi.
Risk of Bursting. Too much air pressure causes a hazardous risk of bursting.
Check the manufacturer's maximum pressure rating for air tools and accessories.
The regulator outlet pressure setting must never exceed the maximum pressure rating of the
tool or accessory.
UNIVERSAL QUICK CONNECT BODY
The universal Quick Connect body (E) accepts the three most popular styles of Quick Connect
(E) plugs: Industrial, automotive, and ARO. One hand push-to-connect operation makes
connections simple and easy.
DRAIN VALVE
The drain valve (H) is located at the base of the air tank and is used to drain condensation at the
end of each use. See Draining Air Tank under Maintenance.
COOLING SYSTEM
This compressor contains an advanced design cooling system. It is normal for this fan to blow
air through the vent holes in large amounts. The cooling system is working when air is expelled.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not available until the compressor has
raised the air tank pressure above that required at the air outlet.
AIR INTAKE FILTER
The filter (J) is designed to clean air entering the pump. To ensure the pump continually receives
a clean, cool, and dry air supply the filter must always be clean and the filter intake must be free
from obstructions.
MOTOR OVERLOAD PROTECTOR
The motor has a thermal overload protector. If the motor overheats for any reason, the overload
protector will shut off the motor. The motor must be allowed to cool down before restarting.
To restart:
1. Set the Auto/Off (A) lever to Off and unplug unit.
2. Allow the motor to cool.
3. Plug the power cord into the correct branch circuit receptacle.
4. Set the Auto/Off (A) lever to AUTO position.
INSTALLATION
ASSEMBLY
INSTALLING HOSES
Risk of unsafe operation. Firmly grasp hose in hand when installing or discon-
necting to prevent hose whip.
1. Ensure Regulated Pressure Gauge (C) reads 0 psi.
2. Grasp the hose at the Quick Connect (E) plug and push the plug into the Quick Connect (E)
body. Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING HOSES
Risk of unsafe operation. Firmly grasp hose in hand when installing or discon-
necting to prevent hose whip.
1. Ensure Regulated Pressure Gauge (C) reads 0 psi.
2. Pull coupler on Quick Connect (E) body back to release Quick Connect (E) plug on hose.
8