signal at the beginning of a cycle for interface
kit connection. (i.e. is High in datum position).
17
'M' port, is tapped M5. Used for sequence
control. The signal is produced when the tool
is at rest.
(*)
Available in KIT form. See Desoutter Catalogue
for details"
The 'M' port is intended for the operation
of pilot valves. lt must not be used as a
source of air supply for other uses.
Simple Control Valve
2
Figure 4
1a
Position for 'SW1' proximity switch, using
actuating pin
1b
Position for 'SW1' proximity switch, using
sleeve on extension tube
2
Position for 'SW2' proximity switch, detects a
signal when the tool has reached depth
3
Retract Air port, tapped 1/8 in. BSP
4
Advance Air port, tapped 1/8 in. BSP
This control valve block module is used when
the tool is to be controlled remotely.
Both (1a) and (1b) detects a signal when the tool
is at the datum position.
External circuitry will be required to
control the speed of advance and retract
feeds.
When using simple control block replace
screw (55) with extended head screw
(383983).
11/2016
Accessories
Mounting Clamps
A range of clamps bases and columns are
available.
Full details obtained from Desoutter.
Hydraulic Check Unit (HCU)
The tool will function satisfactorily, when drilling
a blind hole at the set feed rate.
Should it be required to break through the
material and possibly through into another hole,
feed acceleration will occur with possible drill
breakage.
To obviate this, the fitment of an HCU is strongly
recommended.
1a
Request information from Desoutter.
1b
Peck Feed Drills
The Desoutter Peck Feed Drill System should be
used when the depth of the hole to be drilled is
five or more times the hole diameter.
This helps clear drill chips and avoids excessive
overheating of drill bit.
Hole size accuracy can be improved and drill bit
run-out can be kept to the minimum.
Request information from Desoutter.
3
SETTING DRILLING OPERATION
The drill must be at least 6mm (0.25in) above
the work piece.
4
HCU
8
Figure 5
This setting details a unit with a HCU,
reference to the HCU should be ignored
when setting the standard tool.
● Set the gap between the (1) and (2) to equal
the depth of drilling required PLUS the
distance the bit is above the work piece, by
sliding (3).
● Lock in position with (4) to the recommended
torque.
● Position the HCU in (3).
● Set the gap between (6) and (7) to a distance
as required above the work piece.
6
4
9
20mm
min.
440933
Issue no : 12
Series : C
7
2
1
3
1
23 / 68