Water starts out hot and becomes cooler as handle is rotated counter
clockwise.
This is a potentially hazardous situation and should be corrected before using
the unit. Check the hot and cold inlet positions (hot- left cold-right). If you have
a back to back installation, (where hot and cold inlets are reversed) refer to
Valve Body instruction sheets for back to back installation.
Water flows from the shower head while filling the tub.
Check the position of the Valve Body (J). The letters "SHWR" should be cast
into the top and "TUB" on the bottom.
Water doesn't get hot enough.
Remove Handle (A), Sleeve (B) and Flange (C) and then refer to section 7 for
adjusting temperature range.
Water flows from the tub spout while using the shower.
The seal inside of the diverter mechanism may have become dislodged. The
Spout (H) may need replacement.
MAINTENANCE & CARE
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Pfister
Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!